Sign In | Join Free | My burrillandco.com
Home > HVAC & Building Management System >

SE509 Ultrasonic Energy Meter for HVAC Building Management System Two Temperature Sensors and Ultrasonic Flow Meters

    Buy cheap SE509 Ultrasonic Energy Meter for HVAC Building Management System Two Temperature Sensors and Ultrasonic Flow Meters from wholesalers
     
    Buy cheap SE509 Ultrasonic Energy Meter for HVAC Building Management System Two Temperature Sensors and Ultrasonic Flow Meters from wholesalers
    • Buy cheap SE509 Ultrasonic Energy Meter for HVAC Building Management System Two Temperature Sensors and Ultrasonic Flow Meters from wholesalers
    • Buy cheap SE509 Ultrasonic Energy Meter for HVAC Building Management System Two Temperature Sensors and Ultrasonic Flow Meters from wholesalers
    • Buy cheap SE509 Ultrasonic Energy Meter for HVAC Building Management System Two Temperature Sensors and Ultrasonic Flow Meters from wholesalers

    SE509 Ultrasonic Energy Meter for HVAC Building Management System Two Temperature Sensors and Ultrasonic Flow Meters

    Ask Lasest Price
    Brand Name : Flo-Instru
    Model Number : SE509
    Certification : ISO:9001, CE
    Payment Terms : T/T
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    SE509 Ultrasonic Energy Meter for HVAC Building Management System Two Temperature Sensors and Ultrasonic Flow Meters

    SE509 Ultrasonic Energy Meter

    Clamp-on simple type ultrasonic energy meter.


    Introduction

    SE509-PT1000 ultrasonic energy meter, which is used for measuring individual energy consumption in any liquid heating/cooling systems. The meter is supplied complete with flowmeter and temperature sensor, which can makes the system real-time detect the temperature of supply and return pipe.

    The temperature sensor is to use conversion element characteristics of electromagnetic parameters change with temperature, the temperature and temperature related parameters for testing device.The resistancechange of the temperature change can be converted to known as thermal resistance sensors.

    SE509-PT1000 Meter provides highly accurate thermal energy measurement in chilled water,hot water and condenser water systems based on
    signal inputs from two temperature sensors and ultrasonic flow meters.


    Main Features

    Flo-Instruments SE509 ultrasonic flowmeter offers high-accurate, repeatable and stable flow measurement for liquids. It is made of strong metal case. Combined the outstanding performance transducer with high industrial grade material, it's ideal for pipes size from 1''(25mm) up to 80''(2000mm) in diameter. IP68 transducers that are easy to install requires this pipe not to be cut, thus reducing installation and labor costs. Clear and obvious interface makes it very convenient to operate.


    Working Principle

    Introduction to TVT

    TVT(Transit-Time Vortex) technology represents a cutting-edge approach to ultrasonic flow measurement, combining the principles of transit-time ultrasonics with the capability to harness the vortex shedding phenomenon, delivering unparalleled accuracy and versatility in ultrasonic flow meters. This innovative integration technology enhances the accuracy, versatility, and performance of ultrasonic flow meters, making them well-suited for a wide range of applications across various industries and is a valuable solution for industries requiring precise flow measurements in varying flow conditions.

    • Enhanced Accuracy in Turbulent Flows:

    TVT technology excels in applications where fluid flow conditions vary between laminar and turbulent. The incorporation of vortex shedding data enhances accuracy in challenging flow environments.

    • Versatility in Fluid Types:

    TVT technology is versatile and suitable for a wide range of fluid types, including liquids with varying viscosities and densities.


    Specifications

    Performance Index
    Flow Range0m/s ~ 12m/s(0ft/s ~ 40ft/s)
    AccuracyValued ±1.0%
    Repeatability2.0%

    Pipe Diameter

    Range(Optional)

    DN25~DN2000 (1’’ ~ 80’’)
    Measuring Mediumwater, sea water, oil,alcohol...
    Pipe Material(Optional)PVC, stainless steel, carbon steel, copper...
    Function Index
    Communication InterfaceModBus RS485, 4~20mA, Maximum load: 750Ω, OCT upper and lower limit alarm
    Power Supply24V DC
    Keyboard4 touch keys
    Display2.2" TFT LCD 320*240
    TemperatureTransmitter ambient temperature: -40℉~140℉(-40℃~60℃)
    Transducer measurement medium: -40℉~176℉(-40℃~80℃)
    PT1000 Temp. Sensor: 35.6℉~221℉(2℃~105℃)
    HumidityRH 0~95% RH,non-condensing
    IPIP54
    Flow UnitSupport metric unit selection,Cubic Meters(m3), Liters(l),USA Gallons(gal).
    /hour, /min, The factory default unit is m3 per hour.
    Energy UnitGiga Joule (GJ), Kilocalorie (Kc), KWh, BTU
    Physical Characteristics
    TransmitterAluminum alloy
    SensorClamp-on
    CableStandard length: 10m
    PT1000 Reference Table
    Temperature0123456789
    ()Resistance value (Ω)
    01000.01003.91007.81011.71015.61019.51023.41027.31031.21035.1
    101039.01042.91046.81050.71054.61058.51062.41066.31070.21074.0
    201077.91081.81085.71089.61093.51097.31101.21105.11109.01112.8
    301116.71120.61124.51128.31132.21136.11139.91143.81117.71151.5
    401155.41159.31163.11167.01170.81174.71178.51182.41186.21190.1
    501194.01197.81201.61205.51209.31213.21217.01220.91224.71228.6
    601232.41236.21240.11243.91247.71251.61255.41259.21263.11226.9
    701270.71274.51278.41282.21286.01280.81293.71297.51301.31305.1
    801308.91302.71316.61320.41324.21320.81331.81335.61339.41343.2
    901347.01350.81354.61358.41362.21366.01369.81373.61377.41381.2
    1001385.01388.81392.61396.41400.21403.91407.71411.51415.31419.1

    Quality SE509 Ultrasonic Energy Meter for HVAC Building Management System Two Temperature Sensors and Ultrasonic Flow Meters for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Flo-Instruments Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)